EasyManua.ls Logo

Atlas Copco QAS 500

Atlas Copco QAS 500
130 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 29 -
4.2.4 Setting the Qc1002™
4.2.4.1 Pushbutton and LED functions
Following pushbuttons are used on the
Qc1002™:
Following LEDs are used on the Qc1002™:
1
ENTER: Is used to select and
confirm changed settings in the
Parameter list.
2UP: Is used to scroll through the
display information and to adjust
parameter value upwards.
3
DOWN: Is used to scroll through
the display information and to
adjust parameter value
downwards.
4
BACK: Is used to leave the
Alarm pop-up window, to leave
the Parameter list and to leave
menu's without change.
5
REMOTE MODE: Is used to
activate the remote mode. The
LED indicates if the gen-set is put
in Remote Mode.
6
START: Is used to start the unit
in Manual Mode.
7
STOP: Is used to stop the unit in
Manual or Remote Mode (always
with shutdown!). When the unit
is stopped with the STOP button
in Remote mode, it will
automatically go to Manual
Mode.
1Power Green LED indicates that the unit is
powered up.
2Remote Green LED indicates that the Remote
Mode is selected.
3
Start/
Stop
Green LED indicates that the
engine is running.
4Alarm Flashing red LED indicates that an
alarm is present. A continuous red
LED indicates that the alarm has been
acknowledged by the user. The exact
alarm is shown on the display.
2
1
4
3
Qc1002 CAN
v x.xx.xx

Table of Contents