4.3.4.2 Qc2002™ menu overview
At Qc2002™, the LCD will show following
information:
–in Normal condition (scroll through the
information using UP and DOWN):
Status (eg: preheat, crank, cooldown, extended
stop time, …) (pop-up: this display is only
shown when a Special status comes up)
Line voltages of the generator
Controller type & version
Parameter list
Alarm list
LOG list
Service Timer 1 & Service Timer 2
•Battery Voltage
•RPM (speed)
Coolant temperature
Oil pressure
Fuel level
kWh counter
Power factor, the frequency of the generator
and the frequency of the mains
Line voltage, frequency and active power of
the generator
Active, reactive and apparent power of the
generator
Generator currents
Phase voltages of the mains
Line voltages of the mains
Phase voltages of the generator
–in Alarm condition (scroll through the
information using UP and DOWN):
a list of all active Alarms
It's possible to scroll through the views, using the UP
and DOWN buttons. The scrolling is continuous.
If a Special status comes up, the Status Display is
shown.
If an Alarm comes up, the Alarm Display is shown.
4.3.4.3 Qc2002™ menu description
Status Display (pop-up window)
In case special statuses are entered, a pop-up window
will automatically be entered for as long as the status
is active.
The background screen is not updated when the status
pop-up window is active.
These special statuses are:
PREHEAT
START OFF/
EXTENDED
STOP TIMER
COOLDOWN

Table of Contents