259
ATmega8535(L)
2502K–AVR–10/06
Two-wire Serial Interface Characteristics
Table 112 describes the requirements for devices connected to the Two-wire Serial Bus. The ATmega8535 Two-wire Serial
Interface meets or exceeds these requirements under the noted conditions.
Timing symbols refer to Figure 127.
Notes: 1. In ATmega8535, this parameter is characterized and not 100% tested.
2. Required only for f
SCL
> 100 kHz.
3. C
b
= capacitance of one bus line in pF.
Table 112. Two-wire Serial Bus Requirements
Symbol Parameter Condition Min Max Units
VIL
Input Low Voltage -0.5 0.3 V
CC
V
VIH
Input High Voltage 0.7 V
CC
V
CC
+ 0.5 V
Vhys
(1)
Hysteresis of Schmitt Trigger Inputs 0.05 V
CC
(2)
–V
VOL
(1)
Output Low Voltage 3 mA sink current 0 0.4 V
tr
(1)
Rise Time for both SDA and SCL 20 + 0.1C
b
(3)(2)
300 ns
tof
(1)
Output Fall Time from V
IHmin
to V
ILmax
10 pF < C
b
< 400 pF
(3)
20 + 0.1C
b
(3)(2)
250 ns
tSP
(1)
Spikes Suppressed by Input Filter 0 50
(2)
ns
I
i
Input Current each I/O Pin 0.1V
CC
< V
i
< 0.9V
CC
-10 10 µA
C
i
(1)
Capacitance for each I/O Pin 10 pF
f
SCL
SCL Clock Frequency f
CK
(4)
> max(16f
SCL
, 250kHz)
(5)
0 400 kHz
Rp Value of Pull-up resistor
f
SCL
100 kHz
f
SCL
> 100 kHz
t
HD;STA
Hold Time (Repeated) START Condition
f
SCL
100 kHz 4.0 µs
f
SCL
> 100 kHz 0.6 µs
t
LOW
Low Period of the SCL Clock
f
SCL
100 kHz
(6)
4.7 µs
f
SCL
> 100 kHz
(7)
1.3 µs
t
HIGH
High Period of the SCL clock
f
SCL
100 kHz 4.0 µs
f
SCL
> 100 kHz 0.6 µs
t
SU;STA
Set-up Time for a Repeated START
Condition
f
SCL
100 kHz 4.7 µs
f
SCL
> 100 kHz 0.6 µs
t
HD;DAT
Data hoLd Time
f
SCL
100 kHz 0 3.45 µs
f
SCL
> 100 kHz 0 0.9 µs
t
SU;DAT
Data Setup Time
f
SCL
100 kHz 250 ns
f
SCL
> 100 kHz 100 ns
t
SU;STO
Setup Time for STOP Condition
f
SCL
100 kHz 4.0 µs
f
SCL
> 100 kHz 0.6 µs
t
BUF
Bus Free Time between a STOP and START
Condition
f
SCL
100 kHz 4.7 µs
f
SCL
> 100 kHz 1.3 µs
V
CC
0.4V
3mA
----------------------------
1000ns
C
b
-------------------
Ω
V
CC
0.4V
3mA
----------------------------
300ns
C
b
----------------
Ω

Table of Contents