Clou Pellet / Clou Compact Pellet User instruction 10 English
We recommend a restart temperature of 1.0 °C and a switch-off temperature of 0.6 °C as standard set-
tings.
Your authorised Austroflamm service engineer will discuss with you the settings you require during the
initial commissioning stage.
Starting up the pellet stove for the first time
The stove body, many steel and cast iron components and the flue pipes are varnished with heat-re-
sistant paint. When the stove is started up for the first time, the temperature causes the paint to dry
and harden. This results in odours. Please avoid touching the painted surfaces during this phase and
ensure that the room is well ventilated.
In order for the varnish to cure quickly, we recommend running the stove at the highest power setting
for 3 - 4 hours when it is first put into operation.
FILLING THE AUGER SHAFT MANUALLY:
Before starting the appliance for the first time, the pellet
auger shaft must be filled manually. To do this, press the
black RESET button (see illustration on the right) contin-
uously for more than 3 seconds. While this button is de-
pressed, the auger continuously feeds pellets into the
auger shaft. It takes about 3 minutes for the auger to fill
the shaft. As soon as the first pellets fall into the burn
pot, the manual filling process can be ended.
IMPORTANT: After manually filling the auger, be sure to
empty the burn pot of any pellets that have dropped
into it. You may then start your pellet stove.