Clou Pellet / Clou Compact Pellet User instruction 7 English
The flue pipe must be connected to the rear of the stove.
• The chimney must be designed according to the technical data of the stove (Technical data in
this manual).
• The horizontal length of the flue pipe should not exceed 2.5 m.
• The flue pipe must have no more than three 90° elbows. Each elbow should have a tight clean-
ing aperture.
• The chimney must be resistant to condensation.
• To ensure your pellet stove operates correctly, a chimney draught of 3 Pa - 12 Pa is stipulated.
• Austroflamm GmbH assumes no liability neither responsibility for connecting our heating ap-
pliances to shared flue pipes/chimneys – multiple occupancy. For more information, refer to a
chimney sweep and check your national, regional, and local building regulation.
Fuel
Pellets
Different pellet qualities cause different residues in the burn pot of
the pellet stove when burning. We therefore strongly recommend
using pellets that do not contain artificial binding agents and there-
fore generate minimal unburnt residue.
ENplus-A1 certified pellets satisfy this requirement.
When storing the pellets, it is essential to ensure that they are stored in a dry place and free of contam-
ination. Damp pellets result in poor combustion and clog the auger shaft.
Electrical connection
Your stove is designed for connection to a 230 V~ 50 Hz mains supply.
The connection cable for your stove is included in the accessory pack.
The mains connection socket is located on the rear of the appliance.
This is protected by a slow-blow T2.5 A glass tube fuse
The power consumption of your stove is:
in STAND BY: approx. 5 W
during OPERATION: approx. 20 W
during AUTOMATIC IGNITION: approx. 320 W