Replace the push-button panel
Electronic control unit broken
Replace the electronic control unit
The platform descent is not properly
controlled
Lowering valve screw not tight
Replace the lowering valve
The platform does not rise
Lowering valve screw not tight
Replace the lowering valve
Electro-pump remote switch broken
Replace the electro-pump remote
switch
Replace the push-button panel
Electronic control unit broken
Replace the electronic control unit
Insufficient battery charge
Clean the earth connection
Hydraulic power unit broken
Replace the hydraulic power unit
Max. speed control at excessively
low levels
Calibrate the speed to an
appropriate level
The platform does not stop at the
loading surface when rising
Micro M1 not connected correctly
Correctly connect micro M1
Intermittent power on the micro M1
line
Restore continuous power to the
micro M1 line
Micro M1 cam not adjusted correctly
Correctly adjust the micro M1 cam
The platform does not close
Lowering valve screw not tight
Pressure switch not correctly
calibrated
Correctly calibrate the pressure
switch
Replace the lowering valve
Electro-pump remote switch broken
Replace the electro-pump remote
switch
Replace the push-button panel
Electronic control unit broken
Replace the electronic control unit
The platform does not close
completely
Pressure switch not correctly
calibrated
Correctly calibrate the pressure
switch
Max. speed not correctly calibrated
Recalibrate the max. speed