The troubleshooting table below helps to rapidly solve any operating faults.
For any malfunctions that are not listed below or are due to mechanical and/or
hydraulic breakages, contact your nearest authorised service centre.
The warning light in the cab does
not come on
Hydraulic power unit fuse open
Replace the main power fuse
Replace the cab warning light
Electronic control unit fuse blown
Replace the electronic control unit
fuse
The platform does not open
Push-button panel not correctly
connected
Correctly connect the push-button
panel
Intermittent power on the solenoid
line
Restore continuous power to the
solenoid line
Lowering valve solenoid broken
Replace the lowering valve solenoid
Hinges locked (models SKY and
BBW)
Replace the lowering valve
Replace the push-button panel
Electrical control unit broken
Replace the electrical control unit
The platform movement is not
aligned
Hydraulic cylinder rod bent
The platform does not stop at the
loading surface when opening (item
9 in list of components)
Micro M1 not connected correctly
Correctly connect the control wire
Intermittent power on the micro M1
line
Restore continuous power to the
micro M1 line
Micro M1 cam not adjusted correctly
Correctly adjust the micro M1 cam
The platform does not descend
Push-button panel not correctly
connected
Correctly connect the push-button
panel
Intermittent power on the solenoid
line
Restore continuous power to the
solenoid line
Lowering valve solenoid broken
Replace the lowering valve solenoid
Replace the lowering valve