EasyManua.ls Logo

Automation Technology C2-2040-GigE - Description of Modes for Triggering of Sequencer;Frame and Profile Acquisition

Automation Technology C2-2040-GigE
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
38
C2 Series User Manual Rev. 1.9
Description of Modes for Triggering of Sequencer/Frame and Profile
Acquisition
No.
Sequencer/Frame Trigger Mode
Profile Trigger Mode
(PTM)
0
Free-run
PTM0 (free-run)
PTM1 (IN1)
PTM2 (IN2)
1
Start/stop over camera input 1 / 2
Continuous frame acquisition is started with the rising edge
of camera input 1 (IN1) and stopped with rising edge of
camera input 2 (IN2)
When “stop” occurs, the frame is not transmitted
immediately over the GigE interface but the camera
continues to acquire profile data, until the predefined frame
height is reached.
PTM0 (free-run)
PTM3 (RS422)
2
Trigger one frame over camera input 1
Single frame acquisition is triggered over the rising edge of
camera input 1 (IN1)
PTM0 (free-run)
PTM2 (IN2)
PTM3 (RS422)
trigger start of sequencer
(frame trigger)
t
trigger stop of sequencer
trigger start of sequencer
(frame trigger)
t
IN1

Table of Contents