38 
   C2 Series User Manual Rev. 1.9 
Description of Modes for Triggering of Sequencer/Frame and Profile 
Acquisition 
 
Sequencer/Frame Trigger Mode  
Profile Trigger Mode 
(PTM) 
Start/stop over camera input 1 / 2 
Continuous frame acquisition is started with the rising edge 
of  camera  input  1  (IN1)  and  stopped  with  rising  edge  of 
camera input 2 (IN2) 
 
 
When  “stop”  occurs,  the  frame  is  not  transmitted 
immediately  over  the  GigE  interface  but  the  camera 
continues to acquire profile data, until the predefined frame 
height is reached. 
 
Trigger one frame over camera input 1 
Single frame acquisition is triggered over the rising edge of 
camera input 1 (IN1) 
 
 
trigger start of sequencer
(frame trigger) 
t
trigger stop of sequencer 
trigger start of sequencer
(frame trigger) 
t
IN1