In other cases, the LCD only indicates the resistance value.
If the resistance value is greater than 200kΩ , the LCD will
show “0L”.
You can use the probe tip to pierce the plastic insulation on a
wire. This means that you can test the circuit without discon-
necting anything.
There is also another way to prove continuity of connections to
ground or battery. Power up the connection using the power
switch. If the circuit breaker trips you know that you have a good
solid low resistance connection.