105
TC Power cut limit
Launch control
You enable this function by assigning it an I/P before you can use it.
You assign I/Ps under "M1","I/P switches".
Launch control can also be used as a speed limiter.
Launch cut mode
Launch cut mode.Options are
1. Ignition cut
2. Fuel cut
3. Ign & fuel cut
Launch rpm trig
Rpm below that enable launch control.
Launch TPS
Throttle position below which allows launch control
Launch kph
Vehicle speed below which allows launch control
Launch RPM
Rpm that launch begins at
Launch rate
When in launch mode, will ramp the "Launch revlimit" from the "Launch rpm" at
the "Launch rate"(Rpm/sec) until launch is terminated.
Launch ends
If launch is active, will be terminated above this vehicle speed.
Launch retard
Timing subtracted from the ignition timing during Launch control. Can help building
boost on a turbocharged engine.
WOT shift
Wide Open Throttle gear shifting.
You enable this function by assigning it an I/P before you can use it.
You assign I/Ps under "M1","I/P switches".
WOT cut mode
WOT Cut mode.
Options are
1. Ignition cut
2. Fuel cut
3. Ign & fuel cut