Un-Protected.-When memory is full logger will start to overwrite the first
data recorded.
Example:- Log time = 10 min
The logger will always have in it's memory the last 10 minutes of
logged data.
Trigger:
External only.-Logger will not start logging until external switch is closed. See
logger wiring diagram.
External & RPM.-Logger will not start logging until external switch is closed and
engine RPM exceeds specified RPM. See logger wiring diagram.
Always.-Logger will start logging any time the ignition is switched on.
RPM Only:-Logger will start logging when specified RPM is exceeded.
o TRIGGERS ONLY WORK WHEN OFF-LINE.
Total log time is displayed in 00:00:00 = Hours:Min:Sec
Retrieve log data
Retrieve data logged data from ECU.
Retried data will be saved to file. Use "Open logged file" from the file menu to view the
data. Data log files can be re-run in "Virtual drive"
Manual logger ctrl
Control ECU data Logger.
Used to start and stop ECU data logger while online. Both PC and ECU memory can be
used at the same time to data log totally different items.
Triggers only work when ECU is OFF-LINE.
Clear ECU logger
Clear ECU data logger memory.
WARNING, Once this is done the ECU logged data will be lost.