Boost modifier table with protection at high intake air temperatures
The Boost modifier table in
will protect the engine against increasing intake air temperatures by taking away from the
Boost setpoint to prevent detonation damages to the engine. The example shows that if the
intake temperature rise above 65 degrees, the Boost setpoint will start to be lowered. At 76
degrees, boost is reduced by 20 KPA. At 95 degrees it is reduced by 40 KPA. And at 100
degrees the boost pressure is reduced by 60 KPA to protect the engine.