If there are many points to be welded ,please set a filter in the pipe(buy from local market)
Please use nitrogen gas or air to remove the dust and water in the pipe,
Please lay out the piping according to the tend towards of the piping, but it is not allowed
more than 3 times curved at the same point of the pipe(if do like this the pipe will become rigid)
When using pipe bending machine, the curvature shall not be too small or it will affect the
refrigerant flow.