AUX DC Inverter Free Match 50HZ R32
2. Parameters Setting
Indoor unit’s parameters can be set by remote controller (YK-L) and wired remote
controller—For after-sales (In indoor side ,After a new PCB was replaced, indoor parameters set
is necessary).
2.1 Parameter Setting table
04
05
15
Model of IDU
Capacity of IDU
Selection of room sensor
DUCT
AMSD-H07/4R3A
02
07
01
AMSD-H09/4R3A
02
09
01
AMSD-H12/4R3A
02
12
01
AMSD-H18/4R3A
02
18
01
Ceilling & Floor
AMCF-H09/4R3A
13
09
01
AMCF-H12/4R3A
13
12
01
AMCF-H18/4R3A
13
18
01
Note:
04】:Model of IDU
05】:Capacity of IDU
15】:Selection of air return temperature sensor; 00 – sensor in indoor unit , 01—Sensor in
wired controller