AUX DC Inverter Free Match 50HZ R32
45
5. Outdoor Unit
5.1 14K, 18K
DC
INVERTER
Model
AM2-H14/4DR3
AM2-H18/4DR3
System Format
1 drive 2
1 drive 2
Capacity
Cooling
Btu/h
13989(6142-15388)
18084(6824-19892)
kW
4.1(1.8-4.51)
5.3(2.0-5.83)
Heating
Btu/h
16378(6995-18015)
19107(7541-21017)
kW
4.8(2.05-5.28)
5.6(2.21-6.16)
Electric Data
Power Supply
V~,Hz,Ph
220~240,50,1
220~240,50,1
Cooling Power Input
W
1240(198-2100)
1750(280-2300)
Heating Power Input
W
1150(198-2100)
1540(280-2300)
Rated Current
(cooling&heating)
A
5.4/5
7.6/6.7
Max current
A
10
11
Max power
KW
2.1
2.3
Performance
SEER/SCOP
W/W
6.16/4.06F
7.07/4.08F
SEER/SCOP
W/W
6.15/4.05L
7.08/4.06L
SEER/SCOP
W/W
6.16/4.06(J)
7.07/4.07(J)
Energy Rate
A++/A+
A++/A+
EER/COP
W/W
3.31/4.17
3.03/3.64
DC Inv.
Compressor
Model
KSN108D22UFZ
KSM135D23UFZ
Quantity
1
1
Type
Rotary
Rotary
Brand
GMCC
GMCC
Capacity
W
3470
4245
Input
W
890
1075
Power Supply
V~,Hz,Ph
220~240,50,1
220~240,50,1
Rated Current
A
6.05
7.1
Operating Frequency
Hz
60
60
Frequency Range
VG74/310ml
VG74/440ml
Refrigerant Oil
ml
10~120Hz
10~120Hz
Outdoor DC
Inverter Fan
Motor
Model
D-40-8
D-40-8
Type
DC Inverter
DC Inverter
Brand
WELLING
WELLING
Quantities
1
1
Insulation Class
E
E
Safe Class
IP24
IP24
Input Power
W
60
60
Output Power
W
40
40
Capacitor
uF
/
/
Speed
r/min
850-350
850-350