Branch 08 - Gravity compensation
Full service access only.
Sub-branch Value
00 - Calibration gravity factor. This is the
gravity factor of the location where the scale
has been calibrated.
As published by the support office of your
national distributor.
Minimum value = 975000
Maximum value = 985000
You must enter a six digit value as the gravity
factors are automatically set to five decimal
places.
01 - Site gravity factor. This is the gravity factor
of the location where the scale is to be used.
If the scale is to be calibrated and used in the same gravity zone, then both gravity
factors should be set to 0.
If you intend to calibrate the scale and then send the scale to a different gravity
zone, you must enter the calibration and site gravity factors.
If you do not know the site gravity factor, you must enter the calibration gravity
factor and send a note with the scale stating that the site gravity factor is to be
entered and needs to be re-verified and stamped before being sold to the customer.
Note: Once the calibration and site gravity factors have been entered, the scale
may not weigh correctly until the scale is at the site.
Branch 09 - Weight display
Full service access only.
Sub-branch Value
00 - Blank net weight display. This sets the
display to either show a negative net weight
or to blank the display when a tare is created
and then removed from the scale.
0 - Negative net weight display.
1 - Blank net weight display.
01 - Weight decimal marker type.
0 - Comma.
1 - Decimal point.
Service Instructions 13