05/10 Version 5.05-00 USER MANUAL Commissioning and Operation
AP5.4 – AP5.6
19
(De)activating the dispensing edge
¯ Only applies to AP 5.4/5.6 dispensers with dispensing edge installed!
Activating Set
« SYSTEM PARAMETER > Periph. device to “Dispenser”.
The printer restarts. Afterwards, an additional menu DISPENSER PARA can be
accessed that contains all of the parameters required for dispensing mode:
For more on the listed parameters, see Info Printouts and Parameters .
Deactivating Set
« SYSTEM PARAMETER > Periph. device to “None”.
Setting the dispenser
Application A The label should be dispensed to that a narrow strip still sticks to the backing
paper above the dispensing edge. After manually removing the dispensed la-
bel, the next label is printed and dispensed.
Set
« DISPENSER PARA > Dispenseposition to -6.0 mm (for strong adhesives, this may
have to be reduced to -8.0mm).
Set
« DISPENSER PARA > Start source to “Light barrier”.
Application B The label should be printed and dispensed after receiving a signal from the
connected foot switch.
Set
« SYSTEM PARAMETER > External signal to “Singlestart”.
Set
« DISPENSER PARA > Dispenseposition to -6.0 mm (for strong adhesives, this may
have to be reduced to -8.0mm).
Set
« DISPENSER PARA > Start source to “Foot switch”.
Parameters Possible settings
Dispenser mode True 1:1 mode (default), Batch mode, Normal 1:1 mode
Dispensing position Configurable in millimetres (default: 0.0mm)
Display mode Remaining qty. in job (default), dispenser counter
Dispense counter Quantity presetting (default = 0)
Application mode Safe mode (default), immediate mode
Start source Foot switch, light sensor (default)
[Tab. 1] Parameters in DISPENSER PARA menu.