EN45
E - USE
2.2.2 - “AUTOMATIC CLOSING” MODE
Description of operation from the closed gate
position:
Activate the complete (or partial) opening
command.
The flashing light will flash (1 flash per second).
1 second later, the gate will start and open fully
(1m20 for partial opening).
When the gate has reached its opening stop, the
flashing light will change how it flashes (1 short
flash every 1.25s): the time delay before closing
will start.
When the time delay is over, the flashing light will
resume its normal pace (1 flash per second). 1
second later, the gate will start and close fully.
The flashing light will stop flashing and the
manoeuvre is complete.
At any time, you can stop the gate’s movement by
activating a command (total or partial).
If you activate the gate control again, the gate will
start in the opposite direction.
If you activate a command during the time delay,
it will be stopped and automatic closure will be
cancelled.
2.2.3 - “COLLECTIVE” MODE
Operation is identical to “automatic closure” mode,
except:
You cannot stop the gate from opening, either
with the gate or pedestrian opening command.
However, you can still stop the movement by
activating an emergency stop part connected
to the “STOP” input (see “emergency stop
explanations).
If you activate the gate command during the time
delay, it is reloaded with the initial time to extend
the time before automatic closure.
If you activate the gate command during closure,
the gate will stop and open again and the time
delay before automatic closure will start.
The pedestrian control is inoperative.
2.3 - EMERGENCY STOP
Should an emergency stop part (punch button) be
connected to the “STOP” input, you can stop the
gate’s movement by activating this emergency
stop part.
In this case, the flashing light will emit double
flashes to signal the anomaly.
If, after 30 seconds, the emergency stop part is
still activated, the flashing light will stop and the
electronic card will go on standby.
To start the gate again, you must deactivate the
emergency stop part (unlock the push button),
then activate the command that had set the gate
in motion to restart the gate’s manoeuvre (no
reverse in direction in this case).
2.4 - PHOTOCELLS (IF INSTALLED)
During closure, if an object or a person obstructs
the infrared beam between the two photocells,
the gate will stop and start opening again. If
automatic closure is activated, the time delay will
start. If at the end of the time delay, the photocell
beam is cut, the gate will wait for the beam to be
released before closing again. If after 3 minutes,
the beam has still not been released, automatic
closure will be cancelled, the system will go on
standby.
Photocells can also be active at the beginning of
the opening process (this is useful if a second
set of photocells is installed – see “Advanced
settings”).
If this is not the case and the beam is cut when
the portal should start to open, the flashing light
will emit double flashes for 30 seconds unless
you activate a command. For the gate to be able
to open, the beam must be unobstructed and a
command must be activated.
2.5 - OBSTACLE DETECTION
During their movement, the panels may encounter
an obstacle.
For safety purposes, if the motors are under too
much strain (the force is adjustable; see “Motor
Force” in the settings), the gate stops and
releases the pressure and the flashing light emits
double flashes for 30 seconds unless a command
is activated.
On activating a command (the same one that was
used to start the movement), the gate starts to
move in the opposite direction.
If an obstacle is detected during closure and
the operating mode is “automatic closure” or
“collective”, the gate will open again and the time
delay will start over.