MAIN MENU
17
1) LANGUAGE
Select the language of the OSD.
2) ADMIN PASSWORD
Click “SETUP” to change the administrator password. The default administrator password is 0000.
When you’re prompted to enter the DVR password, enter the administrator password, and will be shown
on the status bar of the screen and all operations are allowed.
3) OPERATOR PASSWORD
Click “SETUP” to set or change the operator password. .
When you’re prompted to enter the DVR password, enter the operator password, and
will be shown on
the status bar of the screen and the main menu is NOT allowed to access.
4) UPGRADE
Save the upgrade files obtained from your installer or distributor in a compatible USB flash drive, and insert it
into the USB port at the front panel. Then, click “SUBMIT” to start upgrading.
Note: Before using the USB flash drive, please use your PC to format the USB flash drive to FAT32 format
first. For the list of compatible USB flash drives, please refer to “APPENDIX 3 COMPATIBLE USB
FLASH DRIVE LIST” at page 57.
Note: After upgrading firmware, it’s recommended to clear all HDD data for the system to work more
stably. Before clearing all HDD data, please remember to make video backup.
5) BACKUP CONFIG / RESTORE CONFIG
To keep the current configurations after DVR upgrade, insert a compatible USB flash drive into the USB port,
and select “SUBMIT” in “BACKUP CONFIG” to copy the current DVR configurations to a file “System.bin”
and save to your USB flash drive.
To restore the DVR configurations, insert the USB flash drive including “System.bin” to the USB port, and
select “SUBMIT” in “RESTORE CONFIG”.
5.3.2 SYSTEM INFO
SYSTEM
TOOLS BAUD RATE 2400
SYSTEM INFO
HOST ID 000
USB BACKUP R.E.T.R 5
DVD BACKUP AUTO KEY LOCK NEVER
CLEAR HDD HDD-0
RESET DEFAULT SUBMIT
REMOTE CONTROL ID 000
SERIAL TYPE RS485
VIDEO FORMAT NTSC
VERSION 1010-1005-1006-1007
EXIT
1) BAUD RATE
Set the baud rate of the DVR (2400 / 9600 / 19200 / 38400 / 57600 / 115200).
2) HOST ID
Set the ID of the DVR (000 ~ 254).
3) R.E.T.R
Select the timeout in minute after which the R.E.T.R. function will be activated (3 / 5 / 10 / 30).
4) AUTO KEY LOCK