20 english
10.1 Accuracy
The specifications are typical values for the
BTL7-A/C/E/G… at 24VDC and room temperature, with
a nominal length of 500mm in conjunction with the
BTL-P-1013-4R, BTL-P-1013-4S, BTL-P-1012-4R or
BTL-P-1014-2R magnet.
The transducer is fully operational immediately, with full
accuracy after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Repeat accuracy
Typical ±10µm
Sampling rate
Dependent on the nominal length
At nominal length = 500mm
250 µs…5.5 ms
500 µs
Non-linearity at
Nominal length ≤ 500mm
Nominal length >500 to ≤ 5500mm
Nominal length > 5500mm
±50µm
±0.01% FS
±0.02% FS
Temperature coefficient
1)
≤ 30ppm/K
Max. detectable velocity 10m/s
10.2 Ambient conditions
2)
Operating temperature −40°C…+85°C
Operating temperature for UL
(only BTL7-…-KA…)
≤80°C
Storage temperature −40°C…+100°C
Relative humidity <90%,
non-condensing
Rod pressure rating (when installed in
hydraulic cylinders)
For Ø8mm ≤250bar
For Ø10.2mm ≤600bar
Shock rating
Continuous shock
per EN60068-2-27
3)
150g/6ms
150g/2ms
Vibration
per EN 60068-2-6
3)
(note resonant frequency of the rod)
20g,
10…2000Hz
Degree of protection per IEC60529
Connector SR32/SR115
(when attached)
IP67
Cable IP68
3)
10.3 Supply voltage (external)
Voltage, stabilized
4)
:
BTL7-_5_ _-… 10…30VDC
Ripple ≤0.5V
ss
Current draw
(at24VDC)
<120mA
Inrush current ≤500mA/10ms
Reverse polarity protection
5)
Up to 36V
Overvoltage protection Up to 36V
Dielectric strength
(GND to housing)
500VAC
10.4 Output
BTL7-A… Output voltage
Load current
0…10V and 10…0V
≤ 5 mA
BTL7-C… Output current
Load resistance
0…20mA/20…0mA
≤ 500 ohms
BTL7-E… Output current
Load resistance
4…20mA/20…4mA
≤ 500 ohms
BTL7-G… Output voltage
Load current
−10…10V and 10…−10V
≤ 5 mA
Short-circuit resistance Signal cable to 36 V
Signal cable to GND
10.5 Input
Programming inputs La, Lb: High-active
BTL7-_5_ _-… 10…30VDC
Overvoltage protection Up to 36 V
1)
Nominal length 500mm, magnet in the middle of the measuring range
2)
For : Use in enclosed spaces and up to a height of 2000m above
sealevel.
3)
Individual specifications as per Balluff factory standard, resonances
excluded
4)
For : The transducer must be externally connected via a limited-
energy circuit as defined in UL61010-1, a low-power source as defined in
UL60950-1, or a class 2 power supply as defined in UL1310 or
UL1585.
5)
A prerequisite is that no current can flow between GND and 0V in the
event of polarity reversal.
10
Technical data
BTL7-A/C/E/G5 __ -M ____ -K(8)-SR32/SR115/___
Micropulse Transducer - Rod Style