Icon Fault Code Device Status
OSSD
Status
Description
INTF1 Lockout Off
Internal communication failure.
Reset the system using the reset function or cycle the power to the device.
Try using a separate filtered power supply and/or a grounded shielded cable
to connect the scanner to the cabinet to eliminate external causes of the
failure. If the failure persists, contact the factory for support.
INTF2 Lockout Off
Internal communication integrity test failure.
Reset the system using the reset function or cycle the power to the device.
Try using a separate filtered power supply and/or a grounded shielded cable
to connect the scanner to the cabinet to eliminate external causes of the
failure. If the failure persists, contact the factory for support.
INTF3 Lockout Off
Micro integrity test failure - RAM test.
Reset the system using the reset function or cycle the power to the device.
Try using a separate filtered power supply and/or a grounded shielded cable
to connect the scanner to the cabinet to eliminate external causes of the
failure. If the failure persists, contact the factory for support.
INTF4 Lockout Off
Micro integrity test failure - ROM test.
Reset the system using the reset function or cycle the power to the device.
Try using a separate filtered power supply and/or a grounded shielded cable
to connect the scanner to the cabinet to eliminate external causes of the
failure. If the failure persists, contact the factory for support.
INTF5 Lockout Off
Micro integrity test failure - internal peripheral test (safety relevent).
Reset the system using the reset function or cycle the power to the device.
Try using a separate filtered power supply and/or a grounded shielded cable
to connect the scanner to the cabinet to eliminate external causes of the
failure. If the failure persists, contact the factory for support.
INTF7 Lockout Off
Micro integrity test failure - Function and operation test.
Reset the system using the reset function or cycle the power to the device.
Try using a separate filtered power supply and/or a grounded shielded cable
to connect the scanner to the cabinet to eliminate external causes of the
failure. If the failure persists, contact the factory for support.
INTF8 Lockout Off
Micro integrity test failure - Coherence check Up/Uw.
Reset the system using the reset function or cycle the power to the device.
Try using a separate filtered power supply and/or a grounded shielded cable
to connect the scanner to the cabinet to eliminate external causes of the
failure. If the failure persists, contact the factory for support.
INTF9 Lockout Off
Micro integrity test failure - Program coherence check/CRC failure.
Reset the system using the reset function or cycle the power to the device.
Try using a separate filtered power supply and/or a grounded shielded cable
to connect the scanner to the cabinet to eliminate external causes of the
failure. If the failure persists, contact the factory for support.
INTF10 Lockout Off
Micro-FPGA integrity test failure - Diagnostic test failure.
Reset the system using the reset function or cycle the power to the device.
Try using a separate filtered power supply and/or a grounded shielded cable
to connect the scanner to the cabinet to eliminate external causes of the
failure. If the failure persists, contact the factory for support.