Line 27 Scale F3 (multiplier), e.g. to 100.000 for display of an extension
comparison in percentage terms.
* 1,0000
0,0001...9999,99
Line 28
Update time (display repetition)
0 * 0.5 s
1 1 s
2 2 s
3 3 s
4 5 s
5 10 s
6 20 s
7 30 s
8 60 s
Line 29
Time out F1 - F3 (see line 21)
On standstill, after expiry of this period:
a
reset to zero occurs with
measurement functions 0 to 6
0 * 1 s
1 2 s
2 3 s
3 5 s
4 10 s
5 20 s
6 30 s
7 60 s
8 Time out not operational
an update of the display occurs
with function 7 „pulse rate meas.“
0.1 s
0.2 s
0.3 s
0.5 s
1.0 s
2.0 s
3.0 s
6.0 s
9 Time out not operational, with storage of F1, F2 and F3 in the
event of a power failure.
Line 30 Time unit F1
0 * 1/min
1 1/s
2 1/h
Line 31
Time unit F2
0 * 1/min
1 1/s
2 1/h
Line 32
Assignment of the „Max hold“
0 * F1
1 F2
2 F3
Line 33
Assignment of the limit value P1
0 * upper limit value of F1
1 lower limit value of F1
2 upper limit value of F2
3 lower limit value of F2
4 upper limit value of F3
5 lower limit value of F3