Setting
(read only)
Description Value
AM016 Flow temperature °C
AM018 Return temperature °C
AM019 Actual water pressure in central heating system bar
AM024 Current output of the boiler 0/100%
AM027 Outside temperature °C
AM036 Flue gas temperature °C
AM037 Status of the 3-way valve (0: Heating, 1: DHW) 0/1
AM040 Outgoing DHW temperature check °C
AM091 Season mode (0: winter, 3: summer) 0/3
AM101 Internal set point °C
BM000 DHW temperature °C
CM030 Current room temperature for zone °C
CM120 Current operating mode in the zone (0: Disabled, 1: Enabled) 0/1
CM190 Zone ambient set point °C
CM210 Outside temperature in the zone °C
CM280 Zone calculated set point °C
DM001 Temperature of the DHW tank °C
DM002 Outgoing DHW flow speed l/min
DM005 Solar system DHW temperature °C
DM009 Primary operating mode (0: Programming, 1: Manual, 2: Antifreeze/Holiday) 0/1/2
DM019 DHW mode active (1: Comfort, 2: Low, 3: Holiday, 4: Antifreeze 1/2/3/4
DM029 DHW temperature set point °C
GM001 Actual fan RPM rpm
GM002 Actual fan RPM setpoint rpm
GM003 Flame detected (0: Not detected, 1: Detected) 0/1
GM004 Gas valve (0: Open, 1: Closed, 2: Off) 0/1/2
GM007 Start-up (0: Off, 1: On) 0/1
GM008 Actual flame current measured μA
GM012 Contact release signal X16 (0: No; 1: Yes) 0/1
GM013 Boiler shutdown signal input (0: Open, 1: Closed) 0/1
GM044 Reason for shutdown checked (0: None)
1. Heating Stoppage
2. DHW Stoppage
3. Awaiting burner ignition
4. Heating flow temperature above maximum value
5. Heating flow temperature above the starting value
6. Heat exchanger temperature above the starting value
7. Average heating flow temperature value above the starting value
8. Heating flow temperature above the setpoint value
9. Temperature difference between flow and return too great
10. Heating flow temperature above the shutdown value
11. Heat request before the minimum wait time between two consecutive requests
12. Shutdown caused by flame value being too low
13. Solar temperature above the shutdown value
0/13
9.4.1 Statuses and sub-statuses
The STATUS is the operating phase of the boiler at the moment
of display. To view the status, select the parameter AM012. The
SUB-STATUS is the instantaneous operation the boiler is
performing at the moment of display. To view the sub-status,
select the parameter AM014.
9 Settings
600 Combi 2 59