SETUP
NUMBER
SETUP ITEM DISPLAY
P18 Setback Temperature This selects the oven set temperature that the oven will change to when the
temperature setback time has been exceeded in P17. Range is 50°F to 300°F
(10°C to 149°C).
Default is 300.
P19 Lights Mode Select 1 for lights on continuously (when oven is on) or select 0 for automatic
operation. Lights will turn off automatically after 30 minutes of no user activity
(door opened or closed, no buttons pushed).
Default is 0.
P20 Restricted Operator
Mode
0 = Standard
1 = Restricted
Operator Mode
Select 1 for restricted operator mode.
When a program is selected by the operator, the bake Timer Minutes Set
window will display the total bake time of all steps in the program. Standard
operation only displays the minutes in the selected step.
When a program is selected, and the Start button is pressed, the operator
cannot make changes to the Bake Time remaining or the Oven Set temp.
If set for steam, steam is produced in 5 second on, 5 second off intervals for
the time set in P7.
The maximum solenoid on time range that can be set in P7 increases to 60
seconds. Change P7 to 60 when P20 is set for 1.
When P20 is changed from 1 (restricted operator mode) to 0 (standard
mode), P7 must be set below 30 (range 0 to 30 max) or solenoid will energize
continuously for up to 60 seconds. When restricted operator mode is active
[1], all recipes from 20 to 39 the timer shows minutes and seconds in the
display. Default is 0
P21 Advanced Energy
Savings Mode
Select 1 for Advanced Energy Saving. Forcing the oven into an advanced
Auto On - Auto Off mode to conserve energy. Several steps are necessary to
enable this mode. Set the Auto On time to allow the oven to preheat before
the rst bake time. Set the Auto Off time. Press the Auto On/Auto Off button
to illuminate the Timer On/Off indicator. Set P17 & P18 to customer settings.
Auto ON/OFF time is restricted when this feature is set to 1. Auto ON/OFF
times can only be changed while in P21. Default is 0.
P22 Oven Operation Mode 500 = OV500/HBA [Default]
210 = OV210
310 = OV300/OV310
This must be updated to 310 when installing in a OV300/OV310 control panel,
or to 210 when installing in a OV210 control panel as the default is to that of
an OV500 control.
P23 External Alarm Mode Used to decide if the external alarm relay will ash on/off or be a steady on.
This is alarm is activated when a recipe’s time has elapsed.
FLSH = ashing [Default]
STDY = steady
P24 Test Mode Password Test mode password, range 0x0000 to 0xFFFF. This is used by the Baxter
Oven Manager application, required to put the oven into test mode. The
default password value is ‘0000’. While editing the parameter, pressing the
time down key sets the password to the default, pressing the time up key sets
the password to a random value. It is highly recommended that this be a non-
default value when external communications is in use for protection.
P25 Communication Mode
for the RS485 Serial
Port
Requires a power cycle when this is changed.
0 = 1200 baud ASCII, [default]
1 = 9600 baud NAFEM MODBUS RTU,
2 = 9600 baud ASCII
3 = 19200 baud ASCII