* Measured in optimal conditions
** External electrical sources must be within specified voltages, max 100W and ensure double insulation from primary voltages.
TECHNICAL SPECIFICATIONS
DESCRIPTION
ENGLISH
OPENING SENSOR
FOR AUTOMATIC INDUSTRIAL DOORS
1. push buttons
2. front face
3. radar antenna
FALCON: for normal to high mounting (3.5 - 7 m)
FALCON XL: for low mounting (2 - 3.5 m)
This user’s guide is an informative document and
can not be seen as a commitment of result.
Technology: microwave doppler radar
Transmitter frequency: 24.150 GHz
Transmitter radiated power: < 20 dBm EIRP
Transmitter power density: < 5 mW/cm²
Detection mode: motion
Detection zone: FALCON: 4 x 5 m ; FALCON XL: 4 x 2 m (typical at 30° and field size 9)
Min. detection speed: 5 cm/s*
Supply voltage**: 12 V to 24 V AC ±10 % (50 - 60 Hz); 12 V to 24 V DC +30 % / -10%
Max power consumption: < 2 W
Output**:
Max. contact voltage:
Max. contact current:
Max. switching power:
relay (free of potential change-over contact)
30V AC/42V DC
1A (resistive)
30 W
LED-signal: red: detection state, parameter indication; green: value indication
Mounting height: FALCON: 3.5 m - 7m; FALCON XL: 2 m - 3.5 m
Degree of protection: IP65 (IEC/EN 60529)
Temperature range: from -30 °C to + 60 °C
Dimensions: 127 mm (L) x 102 mm (H) x 96 mm (W)
Tilt angles: 0° to 180° vertical
Materials: ABS and polycarbonate
Weight: 400 g
Cable length: 10 or 15 m
4. angle indication
5. bracket
6. cable
User’s Guide for software version 7.2 and higher