Calibration and Adjustment Instructions for MC5 Multifunction Calibrator For Main Firmware Version 1.90
Page 2/16
Contents
General.......................................................................................................... 3
Equipment Required for Performing the Calibration............................................................ 3
Recommended Calibration Points....................................................................................... 4
E module...................................................................................................................................... 4
ET module ...................................................................................................................................4
Pressure modules........................................................................................................................ 4
Calibrating and Adjusting the Calibrator ................................................... 5
Enabling and Starting the Adjustment Mode ....................................................................... 5
Calibration ...........................................................................................................................5
Adjustment of Measurement Ranges.................................................................................. 6
Adjusting the Voltage Measurement in E Module (±50 V) ........................................................... 6
Adjusting the Low Voltage Measurement in E Module (±1 V)......................................................6
Adjusting the Current Measurement in E Module (±100 mA) ......................................................7
Adjusting the Frequency Measurement in E Module (±0.0027 … 50000 Hz).............................. 7
Adjusting the Resistance Measurement in ET Module (0 … 4000 ohm) ..................................... 8
Adjusting the Low Voltage Measurement in ET Module (±500 mV)............................................. 8
Adjusting the Pressure Measurement of a Pressure Module....................................................... 9
Adjusting the Temperature Measurement of the Internal Reference Junction Module.............. 10
Adjustment of Generation/Simulation Ranges ..................................................................11
Adjusting the Current Generation in E Module (0 … 25 mA)..................................................... 11
Adjusting the Resistance Simulation in ET Module (0 … 4000 ohm) ........................................ 12
Adjusting the Low Voltage Generation in ET Module (±500 mV)...............................................13
Adjusting the Frequency Generation in ET Module (2.7 mHz … 50 kHz).................................. 13
Adjusting the Voltage Generation in ET Module (±12 V) ........................................................... 14
Adjusting the Current Generation in ET Module (±25 mA) ........................................................15
Saving Adjustment Data.................................................................................................... 16
Setting the Calibration Date When No Adjustment Was Required ................................... 16
Ending Adjustment Mode .................................................................................................. 16