BEAMEX MC5-IS - User Manual

BEAMEX MC5-IS
164 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
INSTRINSICALLY SAFE
MULTIFUNCTION CALIBRATOR
User Guide
Applies for Main Firmware version 1.90
Dear user,
We have made every effort to ensure the accuracy of the contents of this manual.
Should any errors be detected, we would greatly appreciate to receive suggestions
to improve the quality of the contents of this manual.
The above not withstanding, we can assume no responsibility for any errors in this
manual or their eventual consequences.
We reserve rights to make modifications to this manual without any further notice.
For more detailed technical data about the MC5-IS Multifunction Calibrator, please
contact the manufacturer.
© Copyright 2002, 2003, 2006, 2007, 2008
BEAMEX OY AB
Ristisuonraitti 10
FIN-68600 Pietarsaari
FINLAND
Tel +358 - 10 - 5505000
Fax +358 - 10 - 5505404
E-mail: sales@beamex.com
service@beamex.com
Internet: http://www.beamex.com
8823000 / UEMC5-IS / 002788

Table of Contents

Questions and Answers

  • C
    Cynthia BanksAug 2, 2025
    How to fix wrong temperature readings on BEAMEX Test Equipment MC5-IS?
    • G
      Garrett PittmanAug 2, 2025
      If your BEAMEX MC5-IS Test Equipment displays incorrect temperature readings, consider the following possible causes and solutions: * Thermocouple Type: The thermocouple type selected in MC5-IS may not match the thermocouple being used. Check and select the correct thermocouple type in MC5-IS. * Reference Junction Mode: The selected Reference Junction mode might not be in accordance with the wiring used. Verify and adjust the Reference Junction mode to match the wiring. * Extension or Compensation Cable: The extension or compensation cable type or connections could be incorrect. Inspect and correct the extension or compensation cable setup. * Polarity: The polarity of the cables may be incorrect. Ensure the polarity of the cables is correct.
  • A
    Aaron FischerAug 12, 2025
    Why does my BEAMEX Test Equipment MC5-IS display random readings during thermocouple measurement?
    • G
      guerrerosarahAug 12, 2025
      Random readings during thermocouple measurement on your BEAMEX MC5-IS Test Equipment can occur due to several reasons: * Incorrect connections: Ensure all connections are correctly made. * Broken wiring: Inspect the wiring for any breaks and repair if needed. * Interference: Mobile phones or radio transmitters can affect the measurement. Remove these sources of interference.
  • D
    Dana GallagherAug 22, 2025
    What to do if BEAMEX Test Equipment MC5-IS displays unstable readings during thermocouple simulation?
    • B
      Barbara JordanAug 22, 2025
      If your BEAMEX MC5-IS Test Equipment shows unstable readings during thermocouple simulation, it might be because the instrument under calibration uses voltage pulses to detect an open sensor. The MC5-IS detects these pulses and tries to compensate for them, causing the unstable output. Prevent these pulses for the duration of the calibration.

Summary

Part A, General

MC5-IS Hardware Overview

Details the physical components, modules, and connections of the MC5-IS calibrator.

MC5-IS Firmware Structure

Explains the MC5-IS software structure, functions, and user interface.

Safety Precautions and Approvals

Covers essential safety precautions, warnings, and ATEX/IEC approvals for the MC5-IS.

Part B, Startup and Basic Operation

Performing Measurements

Details how to perform various measurements like voltage, current, resistance, and temperature.

Signal Generation and Simulation

Explains how to generate or simulate electrical and temperature signals with the MC5-IS.

Calibration Procedures

As Found and As Left Calibration

Documents instrument state before and after adjustments, detailing MC5-IS's role.

Calibrating an Instrument

Guides users through selecting, configuring, and performing instrument calibrations with MC5-IS.

Appendix 1: MC5-IS HART Option User Guide

HART Communication in MC5-IS Basic Mode

Explains how to connect to and communicate with HART instruments within MC5-IS Basic Mode.

Calibrating HART Instruments

Guides on selecting and performing calibration procedures for HART instruments using MC5-IS.

BEAMEX MC5-IS Specifications

General IconGeneral
Intrinsically SafeYes
Operating Temperature-10 to 50 °C
Protection ClassIP65
Pressure ModulesExternal pressure modules available
ElectricalVoltage, current, frequency measurement and generation
TemperatureRTD, Thermocouple
CommunicationHART, Fieldbus
DisplayColor Touchscreen
Measurement RangeVaries by function and module. See datasheet for details.
Output RangeVaries by function and module. See datasheet for details.
Communication InterfaceUSB, HART
Power SupplyRechargeable Battery
CategoryPortable Multifunction Calibrator