Product description
EL1918 and EL1918-220022 Version: 2.0.0
4.2 Intended use
WARNING
Caution - Risk of injury!
TwinSAFE components may only be used for the purposes described below!
The TwinSAFE Terminals expand the application area of Beckhoff Bus Terminal system with functions that
enable them to be used for machine safety applications. The TwinSAFE Terminals are designed for machine
safety functions and directly associated industrial automation tasks. They are therefore only approved for
applications with a defined fail-safe state. This safe state is the switched-off and de-energized state. Fail-
safety according to the relevant standards is required.
The TwinSAFE I/O components allow the connection of:
24V
DC
sensors such as
emergency stop push-buttons, rope pull switches, position switches, two-hand switches, safety
switching mats, light curtains, light barriers, laser scanners, etc.
24V
DC
actuators such as
contactors, protective door switches with tumbler, signal lamps, servo drives, etc.
Test pulses
When selecting actuators please ensure that the test pulses of the TwinSAFE component do not
lead to switching of the actuator or a diagnostic message of the TwinSAFE component.
The following TwinSAFE components were developed for these tasks:
The EL1904 is an EtherCAT Terminal with 4 digital fail-safe inputs
The EL2904 is an EtherCAT Terminal with 4 digital fail-safe outputs
The EL6910 is an EtherCAT Terminal with integrated TwinSAFE logic
These TwinSAFE components are suitable for operation on the
Beckhoff EKxxxx series Bus Couplers
Beckhoff CXxxxx series Embedded PCs with E-bus connection
WARNING
System limits
The TÜV SÜD certificate applies to this TwinSAFE component, the function blocks available in it, the
documentation and the engineering tool. TwinCAT 3.1 and the TwinSAFE Loader are permitted as
engineering tools. Any deviations from these procedures or tools, particularly externally generated xml files
for TwinSAFE import or externally generated automatic project creation procedures, are not covered by the
certificate.
WARNING
Power supply from SELV/PELV power supply unit!
The TwinSAFE components must be supplied with 24V
DC
by an SELV/PELV power supply unit with an
output voltage limit U
max
of 36V
DC
. Failure to observe this can result in a loss of safety.
WARNING
Commissioning test
Before the EL1918 can be used for safety-related tasks, a commissioning test must be carried out by the
user so that faulty sensor wiring can be ruled out.
CAUTION
Follow the machinery directive!
The TwinSAFE components may only be used in machines as defined in the machinery directive.

Table of Contents

Other manuals for Beckhoff EL1918

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Beckhoff EL1918 and is the answer not in the manual?

Beckhoff EL1918 Specifications

General IconGeneral
BrandBeckhoff
ModelEL1918
CategoryTouch terminals
LanguageEnglish

Related product manuals