7.2.3.2Surface
Application of an easy-to-clean surface
The application of an easy-to-clean surface facilitates the use of
the XPlanar in cleanrooms and in the pharmaceutical and food in-
dustries.
The surface must not be thicker than 0.5mm. It must be non-mag-
netic and have low electrical conductivity. Beckhoff recommends the
following material for application to the tiles:
• 1.4404 stainless steel plate, up to 0.5mm thick
► Apply surface[1] to the stator surface[2]