EasyManua.ls Logo

Bell System CS106 - Power Supply - Important Safety Information

Default Icon
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CS106/BL106 Combined Door Entry and Coded Access
11
Power Supply - Important Safety Information
The Model 340C Power Supply must be wall mounted on to plasterboard, wood
or a similar non-conductive material, in a protected indoor environment and
close to a 240V AC electrical supply e.g. an electrical cupboard. Connections
to the 240V AC mains supply must be carried out by a qualified electrician or
similar competent person, and made in accordance with accepted safety
practices.
A two pole switch (as provided by a Consumer Unit or Switch Fuse) must be
included to isolate both Live and Neutral during Installation or Maintenance. The
circuit must be protected by a fuse or other current limiting device, rated
according to the capacity of the cable used, up to a maximum of 10A.
Fuse
There is no serviceable fuse inside the model 340C Power Supply. It has an
electronic current / thermal limit which will recover when a fault is removed.