EasyManuals Logo

Bender CC613 User Manual

Bender CC613
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
Function
Dynamic load management (DLM):
The charge controller comes with DLM software, which can be fully used, independent of a backend
connection. It detects which charging current is applied to which phase and thus prevents the occurrence
of peak loads and unbalanced loads. Maximum number of charging points in a network: 250.
Data management and control functionality of the charge controller:
Termination of the charging process after tripping the residual current protective device (RCD) due to a
residual current.
Detection of critical residual currents by the RCM sensor. For the vehicle owner, this can serve as an early
warning, provided that the charge controller is connected to an energy management system and that it
supports this function.
External Modbus interface for advanced control of the controller via an energy management system,
independent of a backend connection.
The charge controller with residual direct current monitoring module (RDC-M) only works in
combination with the measuring current transformer (to be ordered separately).
WARNING
CAUTION! Risk of damage when pulling out the measuring current
transformer plug! If the measuring current transformer plug is
pulled out using too much force, the enclosure and the internal
components may be damaged. Use needle-nose pliers to unlock
the measuring current transformer plug.
2.6 Temperature monitoring - Load current and cooling monitoring
The charge controller is equipped with a temperature sensor, which allows the temperature in the
environment of the charge controller to be estimated. Based on this estimation, it is possible to dynamically
reduce the charging current or even suspend charging. This feature can serve to maintain the temperature
inside the enclosure within the permissible range for the components used in a charging system. Basic
settings can be made via the Manufacturer tab.
The actual temperature is aected by heat generated by the charge controller itself.
10 CC613_D00381_07_M_XXEN/02.2023

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bender CC613 and is the answer not in the manual?

Bender CC613 Specifications

General IconGeneral
BrandBender
ModelCC613
CategoryController
LanguageEnglish

Related product manuals