EasyManua.ls Logo

Bendix/King KFC 400 - Electric Trim Malfunctions; Engine Failure Emergencies (Autopilot Coupled); Manual Autopilot Shutdown

Bendix/King KFC 400
58 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electric Trim Malfunctions Engine Failure Emergencies
(Autopilot Coupled
)
1.
Disengage autopilot.
Consult aircraft flight manual
supplement for procedures.
2.
Follow engine inoperative proce-
dures in airplane operating handbook.
Manual Autopilot Shutdown
In event that the autopilot fails to
shut down automatically due to a
system malfunction, the following
methods will disable the KFC
400
system manually:
1.
Autopilot Disconnectrrrim Interrupt
autopilot and yaw damper, and flight
director in some installations, will dis-
engage.
Switch
-
PRESS AND HOLD.
Both
2.
Manual Electric Trim Switch
-
MOVE TO FORE
OR
AFT POSITION,
THEN RELEASE.
Autopilot disen-
gages; flight director remains
operational.
3.
Go-Around Pushbutton
-PRESS,
THEN RELEASE.
Autopilot disen-
gages; flight director commands a
nose-up attitude.
4.
KMC
440
Autopilot Mode Selector
Key
-PRESS, THEN RELEASE.
5.
Autopilot Circuit Breaker
-
DISABLE.
6.
Autopilot Power Switch
(if
installed)
-Tum OFF.
7.
Avionics Master Switch
-
TURN
OFF.
Consult aircraft flight manual
supplement for your aircraft.
55