A successful preflight test displays PASS and an associated Sequence
Finished Alert tone is heard.
Figure 5 KFC 230 Successful Preflight Test
Failures such as incorrect installation or software version, internal LRU
failure, internal servo failure, internal acceleration sensor failure, or an
incorrect installed pitch trim servo P/N are considered an unsuccessful
preflight test. A failed preflight test displays FAIL and an associated
aural alert tone is played. A power cycle is required after a failed
preflight test. Contact BendixKing Tech Support for additional help if
Fail message persists.
Figure 6 KFC 230 Failed Preflight Test
If the Installation Configuration Check fails, a
.CHECK AP CONFIGURATION annunciation is displayed. Contact
your local BK dealer for additional support.
Figure 7 KFC 230 Check AP Configuration