XPR-9 Series Two-Post Lifts
40
P/N 5900371 — Rev. D2 — May 2023
Mounting the Power Unit
This section describes how to mount the Power Unit for your Lift. You do not need an Electrician to
mount the Power Unit, but you do need an Electrician to connect the Power Unit.
Important: Do not connect the Power Unit to the Hydraulic System or to the power source at this
point in the installation; those connection will be made later.
The Power Unit must be mounted on the Mounting Bracket on the Power Side Post.
To mount the Power Unit to the Power Side Post:
1. Find the supplied M8 hardware and the Vibration Dampener.
2. Carefully remove the Power Unit from the shipping material.
⚠ CAUTION The Power Unit is heavy. BendPak recommends having one person hold the Power
Unit while a second person bolts it into place.
3. Position the Vibration Dampener into place next to the Mounting Bracket on the Power Side Post.
4. Move the Mount Plate on the back of the Power Unit next to the Vibration Dampener.
5. Push one of the Bolts through a hole in the Mount Plate, through the Vibration Dampener, and into
the Mounting Bracket; attach a Nut to the thread end of the Bolt, then tighten the Nut.
6. Repeat Step 4 for the other three Bolts and Nuts.