XPR-9 Series Two-Post Lifts
50
P/N 5900371 — Rev. D2 — May 2023
Installing a Power Disconnect Switch
WARNING A Power Disconnect Switch is not
provided with this equipment.
A Power Disconnect Switch is a National Electrical Code
(NEC) requirement. They are designed to interrupt main
electrical power in the event of an electrical circuit fault,
emergency situation, or when equipment is undergoing
service or maintenance.
Make sure to install a Power Disconnect Switch that is
properly rated for the incoming power source.
Your Power Disconnect Switch must be readily
accessible and installed so that it is in easy reach of the
operator or in their line of sight. The Power Disconnect
Switch must be clearly marked to indicate its purpose.
The figure to the right shows a Power Disconnect
Switch located between the Lift’s power source and its
Power Unit. A quick flip of the switch immediately cuts
power to the Lift.
In the case of your Lift, the location directly above the
Power Unit is being used by the Lowering Handle, so
your Electrician may want to move the Power
Disconnect Switch location up a little.
DANGER Installing a Thermal Disconnect Switch
must be accomplished by a licensed,
Electrician.
Have the Electrician select a UL-listed Power
Disconnect Switch.
Installing a Thermal Disconnect Switch
WARNING Your Lift motor has no thermal overload protection.
Have the Electrician connect a motor Thermal Disconnect Switch or overload device that will make
sure the equipment shuts down in the event of an overload or an overheated motor.
DANGER Installing a Thermal Disconnect Switch must be accomplished by a licensed
Electrician. Do not perform any maintenance or installation on the Lift without first
making sure that main electrical power has been disconnected from the Lift and
cannot be re-energized until all procedures are complete.
High running amperage that exceeds the motor’s full load amps (FLA) rating may result in permanent
damage to the motor.
BendPak strongly recommends you not exceed the rated duty cycle of the Lift motor.