English
12
Allow at least 50 cm of clearance around the exhaust vent.
Minimum 500mm
(19.69 inch)
Minimum 500mm
(19.69 inch)
Minimum 500mm
(19.69 inch)
Minimum 500mm
(19.69 inch)
Minimum 500mm
(19.69 inch)
Minimum 100mm
(3.94 inch)
Minimum 300mm
(11.81 inch)
Minimum 500mm
(19.69 inch)
Ensure that the air intake vents do not recycle hot air from the exhaust vent.
When operating in an enclosed space, make sure that the surrounding air temperature does
not exceed the projector's operating temperature and that the air intake and exhaust vents are
unobstructed.
All enclosures should pass a certied thermal evaluation to ensure that the projector does
not recycle exhaust air. Recycling exhaust air may cause the projector to shutdown even if the
ambient temperature is within the acceptable operating temperature range.