EasyManua.ls Logo

Bentel Security Absoluta Plus 4.10 - A, B, C and D Arming (<PIN> A, B, C or D + ON); Arming Block Conditions; Silencing Alarm Devices; Wrong PIN

Bentel Security Absoluta Plus 4.10
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
n
A, B, C and D Arming (<PIN> A, B, C orD+ON)
+
DO NOT assign Duress PINs to A, B, C or D Mode
Arming commands.
Each user PIN can be set up to manage four different
Arming mode configurations: A, B, C and D. These con
-
figurations determine the Partitions that will Arm, and
those that will Disarm when an A, B, C or D Mode com
-
mand+ON to confirm the choise, is entered at a Key
-
pad, (the final configuration depends on the User PIN
and Keypad Partitions).
+
Keypads can operate ONLY on the Partitions they
are assigned to.
+
You can Arm/Disarm the Partitions separately us
-
ing a 6-digit User PIN, as follows: — type in a
6-digit User PIN followed by the 2-digit ID number
of the Partition concerned , then press ON, OFF, A,
B, as required. Example: If the 6-digit User PIN is
135790, and you want to Arm Partition 13 in Away
Mode, type-in 13579013 then press ON. If you
want to Disarm Partition 13, using the same PIN,
type-in 13579013 then press OFF. If you enter
13579013 then press A, B, Partition 13 will Arm in
accordance with the respective configuration.
n Arming Block Conditions
The display shows a screen like this one if there are any
conditions that prevent partition arming:
Battery trouble
Execute anyway ?
If more block conditions are present, the keypad dis-
plays them by rotating through the conditions every 2
seconds.
At this point you can do one of the following:
a) Press the ENTER key and anyway perform the arm
-
ing request of control panel;
b) press the ESC key to cancel the arming request.
+
Based on the control panel function mode
(EN50131 enabled or disabled) you cannot force
some blocking conditions: for more information see
“Arming Block Conditions” on page 75.
Some blocking conditions can be solved by the user,
others require installer intervention.
n
Silencing Alarm Devices
The quickest way to silence alarm signaling devices (si
-
rens and flashers) is to disarm the system.
+
This operation will not interrupt the ongoing Alarm
call, or end the Alarm call cycle. Therefore, it will be
necessary access the User Menu (access allowed
to Master User PINs only), and stop the Alarm
calls, via the ‘Clear Call Queue’ option.
Tamper events, which occur when the system is dis
-
armed, can be silenced via the “Reset Alarm” and “Out
-
put ON/OFF” option from the User Menu (access
allowed to Master and User PINs).
For further information, refer to “Using Digital
Keys/Cards”.
n
Wrong PIN
If a wrong PIN is entered, on a LCD keypad the display
will show an error message.
May/14/10 10.50
WRONG PIN
After a few seconds the keypad come back in the
“standby status” and the right PIN can be entered
again.
+
After 10 wrong entries the LCD keypad will lock for
90 seconds.
3
On Grade 3 panels, the keypad locks for 90 sec-
onds if 3 consecutive invalid PINs are entered.
Keyboard Locked
Invalid PINS!
Absoluta Plus and Absoluta 630 OPERATIONS FROM LCD KEYPAD 41

Table of Contents