EasyManua.ls Logo

Bentel Security Absoluta Plus 4.10 - Outputs (ON;OFF) (1.6)

Bentel Security Absoluta Plus 4.10
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
n
Alarm Signals Test (1.5)
This option will allow you to test the proper working or
-
der of the alarm signaling devices.
When you select this option, the panel output n. 1 (gen
-
erally connected to the external siren) is activated for 3
seconds and the voice messages and/or the reporting
codes are sent to the telephone numbers assigned to
the General System Alarm event (ask to your installer
for more information).
+
If on output no. 1 there is a wireless siren, the alarm
signals test cannot activate the siren.
1. Press A or B to view the Alarm sign. test option:
USER 1.5
Alarm sign. test
2. Press ENTER to select the option:
Alarm sign. test
Are you sure?
3. Press ENTER to perform the Test.
Alarm sign. test
Done !!
4. Press ESC to step back to the User menu.
n
Outputs (ON/OFF) (1.6)
This option will allow you to silence the Alarm Outputs
(Sirens) and turn the appliances (sprinklers, lights, etc.)
ON/OFF.
1. Press A or B to view the OutputOFF=STOP option:
USER 1.6
OutputOFF=STOP
2. Press ENTER to turn the appliances ON/OFF and
go to “Turn the appliances ON/OFF”, or:
Ø
press OFF to silence the Alarm Outputs
Silence ALL
outputs ?
Ø
press ON to resume the silenced Alarm Outputs
Activate ALL
outputs ?
3a Press ENTER to confirm and go back to step 1.
Turn the appliances ON/OFF
3b. Enter the Identification Number of the required Out
-
put:
On/Off Output 04
4b. Press ENTER: the Keypad will emit a Boop, if the
selected Output is NOT Reserved for appliance
control, else shows
On/Off Output 04
label Output 04
5b. Press:
Ø
ON to activate the Output
label Output 04
Active now
Ø
OFF to deactivate the Output
label Output 04
Deactivated
6b. Press ESC to go back to step 3b.
Absoluta Plus and Absoluta 630 OPERATIONS FROM LCD KEYPAD 45

Table of Contents