TELEPHONE NUMBER VOICE MESSAGES
Use this row for the Telephone
Numbers and Voice Messages
Add. no. DESCRIPTION 1 2 3 4 5 6 7 8 EC 1 2 3 4 5 6 7 8 A T
411 --
Auto-bypass zone 3
5 7A
412 --
Auto-bypass zone 4
5 7A
413 --
Auto-bypass zone 5
5 7A
414 --
Auto-bypass zone 6
5 7A
415 --
Auto-bypass zone 7
5 7A
416 --
Auto-bypass zone 8
5 7A
417 --
Reserved - Do not program!
-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
418 --
Reserved - Do not program!
-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
Programming digital keys (Addresses 419 through 422)
New Random code Address 419
Step 1 Enter 419.
Step 2
Press .
Step 3
Press to confirm and step back to PHASE 1.
Operation Done will be confirmed by a long high-tone beep.
Step 4
Press to exit without saving, and step back to the PHASE 1.
Digital key programming Address 420:
Step 1 Enter 420.
Step 2
Press .
Step 3 Enter a valid key reader number.
Step 4
Press .
Step 5 Enter any key number (1 through 128).
Step 6
Press .
+
If no key number is selected, and is pressed, the digital key number will
correspond to the current number stored in the control panel memory. To program
the digital key features:
IIMPORTANT Digital keys with factory programming can operate this
control panel, however, this will lower the security level considerably. In
order to assure the intended level of security each digital key must be pro-
grammed with a random code.
PROGRAMMING FROM KEYPAD 29