PROGRAMMING FROM KEYPAD
For in-detail information on the following parameters and options refer to the
"PROGRAMMING" chapter.
All the control panel parameters can be programmed from the keypad.
Only the INSTALLER PIN and MAIN USER PINs can access the program-
ming phase.
+
The control panel will be out of service (alarm outputs disabled) during
the programming phase.
Restrictions
The Installer can program all the control panel parameters, with the excep-
tion of Code PINs 1 through 23.
A Main User Code PIN can change all User, Duress and Patrol Code
PINs enabled on the group of partitions it controls (see below).
CODE No. TYPE
ASSIGNED
PARTITIONS
Code1 MAIN USER 1 - 3 - 4
Code2 MAIN USER 2 - 3
Code3 USER 1 - 3
Code4 USER 4
Code5 USER 3 - 4
Code6 PATROL 2
Code7 DURESS 3
Code8 USER 2 - 3
In the example above MAIN USER Code 1 can change its own PIN and
the PINs of: Code 3, Code 4, Code 5 and Code 7.
MAIN USER Code 2 can change its own PIN and the PINs of: Code 6,
Code 7 and Code 8.
NC2TAST or ICON/KP keypads can be connected to the Panel. The key
functions on the NC2TAST and ICON/KP keypads are identical, however, the
key icons differ. The following description refers to the NC2TAST keypad.
Access to programming
The control panel must be disarmed.
INSTALLER
Enter the INSTALLER PIN then press .
PROGRAMMING FROM KEYPAD 5