Chapter 1 Basics Page 4
1. Basics
Features
The 600-DCSM Monitor offers the following features:
2.8” 16 bit TFT LCD colour screen
Auto backlighting on key press. Also controlled by external signal
8 programmable inputs for DC Voltage, Tank, Systems In Operation & Pump monitoring
2 DC Current Inputs
Internal calculation of DC Amp hours and remaining battery capacity (using Peukert’s
equation)
4 button backlit user interface
Onscreen keyboard for easy input of custom labels
Internal buzzer for high and low alarms and external alarm output 1A rated and protected.
Specifications
General
Power Source 8-32 V DC
Max. Current Consumption 140 m/A
Min. Current Consumption 90 m/A (Power Down Mode)
Dimensions (W x H x D) 89mm x 99mm x 19
Input Specifications
DC Voltage 0-32 V DC
DC Current 0-±50 mV @ ±450 A
Tank 0-5 V DC
Pump 0-32 V DC
Systems in Operation 0-32 V DC
Backlight control input 0-32 V DC
Remote alarm output 1A
MAX
@ 12 V DC Sink to ground
USB
Specification USB 2.0 full speed
File System FAT, FAT32