2.7 Electrical connection
General rules
The appliance must be connected to the mains supply by an authorised and qualified person.
– The appliance must be PERMANENTLY connected to the mains supply by means of a CIRCUIT BREAKER which must
be near the appliance and easily reachable by the operator.
– the circuit breaker must be certified by a Quality Certification Body (IMQ or equivalent) and must be indicated as
the means for interrupting the electrical power supply to the appliance.
– The appliance leaves the factory already configured for 1/N 230 V 50 Hz single phase voltage and comes complete
with a power cable and its relative locking system.
– the connection for 3/N/PE 220V 60 Hz three phase voltage must be requested when placing the order, before the
appliance leaves the factory, for us to be able to supply the correct power cable and appropriate locking device.
– The user is obliged to install the power cable of the appliance in compliance with the legal safety standards of the
territory where the appliance is installed.
– Make sure that the mains voltage value corresponds to that written on the CE declaration of conformity attached
to the appliance.
– Make sure that the appliance power cable is intact. If it is damaged, it must be replaced by the manufacturer, by an
authorised support service or by a qualified technician.
Electrical connection
The appliance is delivered with the cable without plug. The client’s qualified technician will be responsible for correct-
ly connecting the appliance to the mains supply.
– Connect the power cable of the appliance to a circuit breaker, never directly to the main line.
– The mains frequency and voltage must correspond to those indicated on the identification plate of the appliance.
Check that the mains voltage at the socket is the nominal voltage +10% when the compressor is switched on.
m
BE CAREFUL
The appliance must be earthed. It is advisable to install a unipolar(or quadripolar) switch disconnecting
device with a gap of at least 3 mm upstream of the socket. This switch is mandatory when the load ex-
ceeds 1000W or when the appliance is connected directly without using the plug. It is advisable to use a
circuit breaker with a high sensitivity differential to avoid switching off the entire system in case of a fault.