Bewacom Technical manual 25
Erasing the memory
Using this function all programmed
information in the Bewacom can be erased and
the unit set back to factory defaults.
1 Set Bewacom to programming mode.
2 Open the Bewacom and turn it around so
the circuit board can be seen.
3 Press the SW1 button (see the wiring
diagram on page 10).
4 Press 112186 on Bewacom’s keypad.
5 Press 112186 again.
Bewacom now has the default settings:
Password: 112233
Opening time: 7 secs
Calling time: 30 secs
Door release from telephone: 0
Background lighting: On
Internal sounder: On
Possibility to call into Bewacom: Off
Hotline Off
Extended opening time Off
Extended calling time Off