3. About the pH probe
The pH sensor must always be in the water, only install it when the pipes will be filled with water, make
sure to keep the little original bottle (bulb protection) for winter storage
• Handle it with CARES
• NO MASSIVE ADDITION of chemical upstream of it
• Probe winterizing: disconnect the cabinet and remove the probe holder. Store it with bulb immersed in its
original bottle filled with fresh water in a tempered and dry place. Close the probe holder with a ½’’ plug.
The pH electrode is composed of glass elements, so handle it with care.
All our electrodes are tested and calibrated with the Combipool pH/Redox on the manufacturing line before
packaging.
No pH electrode could be changed under warranty without prior manufacturer's permission. In this case, in
order to be accepted for review, the probe will necessarily be returned to us in its original bottle filled with
water.
4. Mounting of inlet and outlet tubes