J. PH PROBE CALIBRATION
Before calibration, check that the buffer solutions have not expired. The probe should be calibrated at least
yearly.
1
2
3
4
Wash the probe
Hold the probe in the buffer
solution
5
6
7
8
Press until the
message "CALIBRATION"
is displayed
The message
"Press_CAL"
"Buffer sol pH 7"
is displayed
Press
The message
"Wait 60 s"
"Buffer sol pH 7"
is displayed
If the message
« 7pH Quality’ 100% » is
displayed, go to step 8.
If the message
"Change the probe"
is displayed, press
to exit.
Change the probe and
return to step 1.
Wash the probe
9
10
11
12
Hold the probe in the buffer
solution
Press
The message
"Wait 60 s"
"Buffer sol pH 4"
is displayed
If the message
« 4pH Quality’ 100% » is
displayed, go to step 12.
If the message
"Change the probe"
is displayed, press
to exit.
Change the probe and
return to step 1.
Wash the probe
13
14
15
Press to exit and
save the data
Displays the pH in the pool
Note :
When the EASY CAL
function is selected,
calibration is only
performed for 1 point at
pH7.