MP 030 NM FR
COPYRIGHT BIO-UV - 04/02/2009
MARQUE, MODELES ET BREVETS DEPOSES - PRODUITS EXCLUSIFS
PAGE 21
PRECONISATIONS DE CONTROLES ET MAINTENANCE PREVENTIVE
0
CHANGEMENT DES
LAMPES UV
EN FIN DE VIE :
- SOIT AFFICHAGE DU
MONITEUR MILLENIUM III :
INTENSITE UV <50%
- SOIT TAUX DE CHLORE
COMBINE DANS LE BASSIN
OPERATIONS A CHAQUE
CHANGEMENT
DE LAMPE UV
AU MINIMUM 1
FOIS PAR AN
CONTROLE DE L’ETAT
GENERAL DU REACTEUR
UV
1 REMPLACEMENT DES
JOINTS QUADRING
OBLIGATOIRE OBLIGATOIRE
2 CONTROLE DE LA
PRESENCE DES CALES
TEFLON DE GAINE
QUARTZ
OBLIGATOIRE
3 NETTOYAGE OU
REMPLACEMENT DE LA
GAINE QUARTZ
OBLIGATOIRE
4 REMPLACEMENT DES
RACLEURS DE
NETTOYAGE
PRECONISE
5 NETTOYAGE DU
CAPTEUR UV
OBLIGATOIRE OBLIGATOIRE
6 CONTROLE DU
FONCTIONNEMENT DU
DEBITMETRE
OBLIGATOIRE
7 CONTROLE DE
FONCTIONNEMENT DES
VENTILATEURS :
- NETTOYAGE DES
GRILLES
- REMPLACEMENT DES
FILTRES (SI CONCERNE)
PRECONISE
OBLIGATOIRE
8 ETALONNAGE DU
CAPTEUR UV
UNIQUEMENT LAMPE NEUVE,
GAINE QUARTZ PROPRE OU