COPYRIGHT BIO-UV - 04/02/2009
MARQUE, MODELES ET BREVETS DEPOSES - PRODUITS EXCLUSIFS
PAGE 23
PROCEDURE CHANGEMENT LAMPES ET GAINES QUARTZ
1
LE STERILISATEUR DOIT ETRE
IMPERATIVEMENT
HORS TENSION, ISOLÉ ET VIDANGÉ.
2
DEVISSER ET RETIRER LES 2 CAPOTS DU
REACTEUR.
3
DECABLER LA LAMPE DES DEUX COTES DU
REACTEUR
(SEULEMENT LES CABLES BLANCS
ALIMENTANT LA LAMPE).
4
DE CHAQUE COTE, DEMONTER LES SUPPORTS
LAMPE EN DEVISSANT LES 3 VIS.
5
ASSUREZ-VOUS QUE LA LAMPE SOIT
SUFFISAMMENT REFROIDIE AVANT DE LA
MANIPULER.
6
RETIRER LA LAMPE ACCOMPAGNEE DE SES
SUPPORTS TEFLON (S’IL Y EN A) ET DEPOSEZ-
LA SUR UNE SURFACE PROPRE ET DOUCE.
EFFECTUER CETTE OPERATION DELICATEMENT
SANS TOUCHER LE VERRE DE LA LAMPE AVEC
LES MAINS.
7
DEVISSER LES ECROUS INOX DES DEUX COTES
ET ENLEVER LES RONDELLES ALUMINIUM.
8
RETIRER SOIGNEUSEMENT LA GAINE
QUARTZ :
POUSSER LA GAINE QUARTZ POUR
POUVOIR L’ATTRAPER DE L’AUTRE COTE.
RETIRER ENTIEREMENT LA GAINE
QUARTZ ET SES JOINTS D’ETANCHEITE.
9
NETTOYER LA GAINE QUARTZ AVEC DE
L’ACIDE OU DU VINAIGRE BLANC OU LA
CHANGER SI NECESSAIRE.