Biodom C15 | instructions for use, maintenance and installation | February 2019
26
Figure 7
6.5. ELECTRICAL CONNECTION
Combustion device requires connection to electrical network. Our pellet boilers are fitted with power
supply cable for medium temperatures. If the power supply cable is damaged and must be replaced,
contact our service staff.
Before making electrical connections, make sure that:
the characteristics of electrical wiring meet the data, given on the combustion device;
extraction of smoke gases is earthed in accordance with regulations and local requirements
in force. (Earthing is required by law);
power supply cable must never reach 80 °C above ambient temperature. If you want to
connect the boiler directly to electrical network, you must install a bipolar switch with
minimum distance of 3 mm between contacts, suitable for required electrical voltage and in
accordance with regulations in force. Bipolar switch must always be accessible, even after the
boiler is installed.