KB-206-2 61
Display of the current measured values (analogue
inputs of the controller):
Menu item Function
F4⇒Ai⇒Prt
Modbus: 8966
(read only)
Suction pressure actual value (as saturation temperature)
F4⇒Ai⇒tSC
Modbus: 8961
(read only)
Suction gas temperature actual value
F4⇒Ai⇒dPrt
Modbus: 8967
(read only)
Condensing pressure actual value (as saturation temperature)
F4⇒Ai⇒tCd
Modbus: 8963
(read only)
Discharge gas temperature actual value
F4⇒Ai⇒tES
Modbus: 8964
(read only)
Ambient temperature actual value
F4⇒Ai⇒tCr
Modbus: 8965
(read only)
Cold store temperature actual value