Technical data of power supply
Power connection:
Single--phase a.c. or three--phase current (see specification plate).
Permitted tolerance of power supply (static) normal:
Permitted tolerance of power frequemcy:
Permitted distortion factor of power
supply:
Leakage current of protective ground wire
max.:
At 100 to 400V
Measures to eliminate interferences:
To avoid heavy fluctuations (e.g. on the
application of thyristor--controlled apparatus),
the user may take the following precautions:
Provide a separate power supply to BIZERBA
equipment. Install a capacity--decoupled
isolating transformer or similar device in the
power supply lines to BIZERBA equipment.
+ 6% to -- 10% of nominal value
+ 2% to -- 2% of nominal value
≤ 5 %
3,5 mA
Power frequency: 50 (60) Hz
6.009.98.5.10.02
GENERAL INSTALLATION
OPERATING
ELEMENTS
OPERATION/
SLICING
CLEANING ACCESSORIES
OPERATING
CONDITIONS
BLADE
REPLACE-
MENT
7.3 Air convection
To avoid overheating, a free flow of air around
all parts of the installed machine must be
allowed.
7.4 Limiting values for protection type, temperature and air humidity
Protection type IP 31
Ambient temperature
for operation and storage: +10 to +40°C (+14 to +104 degF)
Relative air humidity
for operation and storage: 90 % (moisture condensation on the machine is
not allowed to occur)
37